Hurricane Door
Wind Door
HVHZ Door Info
Non-HVHZ Door Info
Florida FL Numbers
Frame Info
Tornado Door
1.Door Assemblies are designed to resist exterior blast pressures, minimum, SDI A250.8, physical performance Level A, Model 2, with welded edges.
2.Door Assemblies have successfully passed 1.75 “PSI” of Static Pressure Loading in accordance with ASTM E-330. This pressure was surpassed in both seating and unseating configurations, these seating pressures, have also passed the “Out-swing” requirements of, UFC 4-010-01. Large Missile Impact level “D” was met as well.
3.We are certified under positive pressure testing UL 10 C, IBC 2014, NFPA 80, HMMA 861 and we meet or exceed SDI 100 manufacturing requirements such as Cycle and Twist protocols.
4.The following table shows the constructions specifications and the criteria disciplines’ for our Hollow Metal Doors and Frames tested for Hurricane Wind Loads which carry the “Approved Status” on the Florida Building Commissions” web site, http://www.floridabuilding.org. Door Assemblies described are posted in, FL-16493-R1 and FL16494-R1 for 2017 and also FL-9067.1 for 2014.
Accepted Engineering Practice 2007, ASTM E1300- 2002, ASTM E1886- 2002, ASTM E1996- 2002, ASTM E330- 2002, TAS 201, 202, & 203-1994, ASTM A250 2002 Verified By: Wendell W. Haney, P.E. 54158